4-Shank 64-Channel Probe, 5 mm
64-site A-Series polytrode/tetrode probe, 4 shanks, 5 mm, 160 µm², 150 µm apart
Four mid-length shanks side by side, closely spaced for coverage within one structure, with sites staggered in two columns so neighbouring sites see the same units. Among the 369 probe designs in the design space it is mid-range: 64 sites (a common choice — 65 of 369), 5 mm shanks (a common choice — 108 of 366), a 0.65 mm-deep site array (35th percentile), 207 sites/mm² (47th percentile) and a 0.56 mm³ neural interface (45th percentile).
Small sites read a local patch at higher impedance, sharpening single-unit isolation, packed densely enough to track a unit across neighbouring sites. The mid-length shanks reach structures a few millimetres down.
Orders as a probe-plus-package assembly, in 22 package configurations, 4 of them microdrive-compatible. Silicon 15 µm thick. Z-coat not available on this close-spaced poly layout. Optical stimulation runs from a separate laser or LED source. Research use only.
a4x16_poly2_lin_5mm_20s_150_160
14 specs
| Channels | 64 |
|---|---|
| Shanks | 4 |
| Shank length | 5 mm |
| Shank separation | 150 µm |
| Site layout | Poly2 |
| Site area | 160 µm² |
| Site pitch | 10 µm |
| Vertical span | 645 µm |
|---|---|
| Substrate | Silicon |
| Site material | Iridium |
| Thickness | 15 µm |
| Neural interface volume | 0.560 mm³ (higher than 45% of 369 designs) |
| Site coverage density | 207.4 sites/mm² (higher than 47% of 369 designs) |
| Brain coverage density | 114.3 sites/mm³ (higher than 91% of 369 designs) |
Narrow the options with the filters or pick a card, then add the configuration to your cart. When your cart is complete, get pricing, lead time and usage details in one request; we reply within one business day.
22 options
Configure
Your selection
64-channel 4-shank silicon probe, 5 mm — 15 μm, H64LP_30MM
H64LP_30MMOptions
22 of 22H64LP (30 mm cable) — 64-ch Omnetics
H64 — 64-ch Omnetics
HC64 — 64-ch Omnetics
HZ64 — 64-ch Hirose
MRH64LP_30MM — 64-ch
MRHC64 — 64-ch Omnetics
OH64LP — 64-ch Omnetics
A64 — 64-ch Samtec
OA64LP — 64-ch Samtec
OA64LP_V2 — 64-ch Samtec
OXA64LP — 64-ch Samtec
AV64 — 64-ch
AVH64 — 64-ch
AVI64 — 64-ch Omnetics
AVIH64 — 64-ch Omnetics
F128 — 128-ch Omnetics
FH128 — 128-ch Omnetics
X3_64 — 64-ch Molex
X3_H64 — 64-ch Molex
SEACM64 — 64-ch Samtec
EIB64 — 64-ch Molex
Z64 — 64-ch Hirose
Loading the compatible products…
13 metrics
Each track spans the smallest to the largest value across catalog designs. The band is the range within its family, and the dot is this design's value. “Top N%” is a rank: how many designs have a larger value.
Top 8% of catalog designs
Sites 64 — higher than 92% of catalog designs and 83% of its familyTop 15% of catalog designs
Shanks 4 — higher than 85% of catalog designs and 84% of its familyTop 48% of catalog designs
Shank length 5 mm — higher than 52% of catalog designs and 51% of its familyTop 83% of catalog designs
Shank separation 0.15 mm — higher than 17% of catalog designs and 26% of its familyTop 53% of catalog designs
Maximum site depth 4.97 mm — higher than 47% of catalog designs and 48% of its familyTop 52% of catalog designs
Minimum site depth 4.32 mm — higher than 48% of catalog designs and 36% of its familyTop 49% of catalog designs
Span, x 0.478 mm — higher than 51% of catalog designs and 49% of its familyTop 65% of catalog designs
Span, y 0.645 mm — higher than 35% of catalog designs and 56% of its familyTop 97% of catalog designs
Site pitch, y 0.01 µm — higher than 3% of catalog designs and 11% of its familyTop 40% of catalog designs
Site outline area 0.309 mm² — higher than 60% of catalog designs and 68% of its familyTop 55% of catalog designs
Neural interface volume 0.56 mm³ — higher than 45% of catalog designs and 59% of its familyTop 53% of catalog designs
Site coverage density 207.4 sites/mm² — higher than 47% of catalog designs and 33% of its familyTop 9% of catalog designs
Brain coverage density 114.3 sites/mm³ — higher than 91% of catalog designs and 71% of its family5 notes · Polytrode and tetrode are two ways to cluster · Site area is the isolation variable · Geometry …
17 links · Care, Use and Handling · Choosing an Electrode for Your Experiment · How an Electrode Records Neural Activity …
Cited in 2,342 publications (product line)