4-Shank 64-Channel Probe, 5 mm
64-site A-Series polytrode/tetrode probe, 4 shanks, 5 mm, 160 µm², 190 µm apart
Four mid-length shanks side by side, closely spaced for coverage within one structure, with sites staggered in two columns so neighbouring sites see the same units. Among the 369 probe designs in the design space it is mid-range: 64 sites (a common choice — 68 of 369), 5 mm shanks (a common choice — 108 of 366), a 0.68 mm-deep site array (36th percentile), 158 sites/mm² (43rd percentile) and a 0.65 mm³ neural interface (50th percentile).
Small sites read a local patch at higher impedance, sharpening single-unit isolation, packed densely enough to track a unit across neighbouring sites. The mid-length shanks reach structures a few millimetres down.
Orders as a probe-plus-package assembly, in 22 package configurations, 3 of them microdrive-compatible. Silicon 15 µm thick. Z-coat not available on this close-spaced poly layout. Optical stimulation runs from a separate laser or LED source. Research use only.
a4x16_poly2_lin_5mm_20s_stag_190_160
14 specs
| Channels | 64 |
|---|---|
| Shanks | 4 |
| Shank length | 5 mm |
| Shank separation | 190 µm |
| Site layout | Poly2 |
| Site area | 160 µm² |
| Site pitch | 10 µm |
| Vertical span | 675 µm |
|---|---|
| Substrate | Silicon |
| Site material | Iridium |
| Thickness | 15 µm |
| Neural interface volume | 0.645 mm³ (higher than 50% of 369 designs) |
| Site coverage density | 158.5 sites/mm² (higher than 43% of 369 designs) |
| Brain coverage density | 99.2 sites/mm³ (higher than 87% of 369 designs) |
Narrow the options with the filters or pick a card, then add the configuration to your cart. When your cart is complete, get pricing, lead time and usage details in one request; we reply within one business day.
22 options
Configure
Your selection
64-channel 4-shank silicon probe, 5 mm — 15 μm, A64
A64Options
22 of 22A64 — 64-ch Samtec
H64LP (30 mm cable) — 64-ch Omnetics
X3_64 — 64-ch Molex
X3_H64 (30 mm cable) — 64-ch Molex
H64 — 64-ch Omnetics
HC64 — 64-ch Omnetics
HZ64 — 64-ch Hirose
MRH64LP_30MM — 64-ch
MRHC64 — 64-ch Omnetics
OH64LP — 64-ch Omnetics
OA64LP — 64-ch Samtec
OA64LP_V2 — 64-ch Samtec
OXA64LP — 64-ch Samtec
AV64 — 64-ch
AVH64 — 64-ch
AVI64 — 64-ch Omnetics
AVIH64 — 64-ch Omnetics
F128 — 128-ch Omnetics
FH128 — 128-ch Omnetics
SEACM64 — 64-ch Samtec
EIB64 — 64-ch Molex
Z64 — 64-ch Hirose
Loading the compatible products…
13 metrics
Each track spans the smallest to the largest value across catalog designs. The band is the range within its family, and the dot is this design's value. “Top N%” is a rank: how many designs have a larger value.
Top 8% of catalog designs
Sites 64 — higher than 92% of catalog designs and 83% of its familyTop 15% of catalog designs
Shanks 4 — higher than 85% of catalog designs and 84% of its familyTop 48% of catalog designs
Shank length 5 mm — higher than 52% of catalog designs and 51% of its familyTop 82% of catalog designs
Shank separation 0.19 mm — higher than 18% of catalog designs and 29% of its familyTop 53% of catalog designs
Maximum site depth 4.97 mm — higher than 47% of catalog designs and 45% of its familyTop 53% of catalog designs
Minimum site depth 4.29 mm — higher than 47% of catalog designs and 35% of its familyTop 45% of catalog designs
Span, x 0.598 mm — higher than 55% of catalog designs and 56% of its familyTop 64% of catalog designs
Span, y 0.675 mm — higher than 36% of catalog designs and 57% of its familyTop 97% of catalog designs
Site pitch, y 0.01 µm — higher than 3% of catalog designs and 11% of its familyTop 36% of catalog designs
Site outline area 0.404 mm² — higher than 64% of catalog designs and 76% of its familyTop 50% of catalog designs
Neural interface volume 0.645 mm³ — higher than 50% of catalog designs and 67% of its familyTop 57% of catalog designs
Site coverage density 158.5 sites/mm² — higher than 43% of catalog designs and 24% of its familyTop 13% of catalog designs
Brain coverage density 99.18 sites/mm³ — higher than 87% of catalog designs and 63% of its family5 notes · Polytrode and tetrode are two ways to cluster · Site area is the isolation variable · Geometry …
16 links · Care, Use and Handling · Choosing an Electrode for Your Experiment · How an Electrode Records Neural Activity …
Cited in 2,342 publications (product line)