Every NeuroNexus headstage is built around a DAQ chip, the integrated circuit that amplifies, filters, and digitizes the electrode signals. The chip sets the channel count, the noise floor, the sampling rate, and whether the system can stimulate. This guide compares the Intan RHD and RHS chips, the Neuropixels chips, and the SiNAPS chip, and it describes how a chip is chosen.

Research use only. NeuroNexus products and the procedures described here are for non-clinical research use, and must not be used in human or veterinary medical procedures.

What a DAQ chip does#

A DAQ chip, or neural recording ASIC, is in a headstage or in the base of an active probe. Its analog front end amplifies and filters the signal of each electrode site, its analog-to-digital converter digitizes the signals, and its digital output streams to the data acquisition system. Amplification and digitization close to the electrode keep the small extracellular signals away from the pickup of long analog cables. A single digital link replaces one analog wire per channel, which keeps the cable light enough for a freely moving animal.

Neural tissue → Silicon probe → Package → Headstage (DAQ chip) → DAQ system → Host computer

Intan RHD chips: record only#

The Intan RHD chips are the recording chips in the NeuroNexus headstages. The three chips share one analog front end and differ in channel count and input type (Intan RHD2000 ↗).

ChipChannelsInputs
RHD221616differential (bipolar)
RHD213232unipolar, with a common reference
RHD216464unipolar, with a common reference

Shared specifications:

  • Input-referred noise: 2.4 µV rms (typical)
  • ADC resolution: 16-bit
  • Sampling rate: up to 30 kS/s per channel
  • Bandwidth: programmable, from 0.02 Hz to 20 kHz
  • Input signal range: ±5 mV
  • Digital interface: SPI
  • Supply voltage: 3.2 to 3.6 V

Power depends on the amplifier bandwidth and the sampling rate, and the Intan datasheets give it for each operating condition. The RHD chips are used for acute and chronic extracellular recording, from rodents to large animals.

Intan RHS2116: record and stimulate#

The RHS2116 adds a constant-current stimulator to each of 16 recording channels, so the same electrode can record and stimulate (Intan RHS2000 ↗).

Key specifications:

  • Recording channels: 16, with an input-referred noise of 2.4 µV rms (typical) and 16-bit resolution
  • Stimulation channels: 16, one constant-current stimulator per channel
  • Stimulation current: 10 nA to 2.55 mA, set by an 8-bit DAC with a step size from 10 nA to 10 µA
  • Stimulator supply: up to ±10.7 V, with no more than 14 V between the two rails

The chip has no timers for stimulation pulses. The acquisition system sets the pulse timing through commands to the chip, so pulse width and rate are specifications of the system. On XDAQ, Kontex specifies a temporal resolution of 33 µs and compliance voltages of ±7 V, −4 to +10 V, or −10 to +4 V (X-Series XDAQ System Overview).

The RHS2116 is used for closed-loop stimulation, intracortical microstimulation, and any protocol that records and stimulates through the same electrodes.

Neuropixels chips (imec)#

Neuropixels probes, made by imec, put the recording circuit in the probe base and a switch under every site. One shank has hundreds of selectable sites, and the probe records a chosen subset of them at once (Jun et al. (2017) ↗; Steinmetz et al. (2021) ↗). NeuroNexus does not make Neuropixels. XDAQ acquires them, the Commutator PRO connects up to four of them on a freely moving animal, and Radiens reads their data. The figures below are from imec's published data sheets.

Neuropixels 1.0:

  • Sites: 960 on one 10 mm shank (70 × 24 µm), with 384 recorded at once
  • ADC resolution: 10-bit
  • Sampling: 30 kHz in the spike band (0.3 to 10 kHz) and 2.5 kHz in the LFP band (0.5 to 500 Hz), recorded at the same time
  • Input-referred noise: 5.9 µV rms in the spike band and 9.2 µV rms in the LFP band (typical)
  • Power: about 15 mW

Neuropixels 2.0:

  • Sites: 1,280 on one shank or 5,120 on four shanks 250 µm apart, with 384 recorded at once (the Quad Base version records 1,536 at once from 5,120)
  • ADC resolution: 12-bit
  • Sampling: 30 kHz, in one full band (0.5 Hz to 10 kHz)
  • Input-referred noise: about 6.8 µV rms in the spike band and about 5 µV rms in the LFP band (typical)
  • Power: about 22 mW (about 88 mW for the Quad Base)

Neuropixels probes are used for large-scale single-unit recording along a long, thin shank, with the recorded sites chosen for each session. They record only.

SiNAPS chip#

The SiNAPS chip is the circuit in SiNAPS probes. NeuroNexus partners with Corticale to commercialize SiNAPS probes. An active pixel under every site amplifies and filters the signal of that site, the pixels are multiplexed in modules of 32, and the signals are digitized on the probe. Every site is recorded at once: 256 sites on one shank, or 1,024 sites on four or eight shanks (Angotzi et al. (2019) ↗; Angotzi et al. (2025) ↗).

Key specifications:

  • Sites: 256 (one shank) or 1,024 (four or eight shanks), all recorded at once
  • Resolution: 12-bit
  • Sampling: 20 kS/s per site, fixed
  • Bandwidth: full band, 0.1 Hz to 5 kHz, on every site
  • Input-referred noise: about 6.5 µV rms in the spike band
  • Multiplexing: 32:1, with no headstage
  • Interface: the SiNAPS interface box to Smartbox

SiNAPS probes are used for dense recording in which the whole shank should be in the data in every session, and for multi-shank layouts of up to eight shanks. They record only. Neuropixels, SiNAPS and Silicon Probes: How to Choose compares the two active probes point by point.

Comparison table#

ChipChannels recorded at onceModeNoise (µV rms, spike band)ResolutionSampling
RHD221616Record2.416-bitup to 30 kHz
RHD213232Record2.416-bitup to 30 kHz
RHD216464Record2.416-bitup to 30 kHz
RHS211616, with 16 stimulatorsRecord and stimulate2.416-bitup to 30 kHz
Neuropixels 1.0384 of 960 sitesRecord5.910-bit30 kHz spike · 2.5 kHz LFP
Neuropixels 2.0384 of 1,280 or 5,120 sitesRecordabout 6.812-bit30 kHz
SiNAPSevery site, 256 or 1,024Record6.512-bit20 kHz, fixed

The Intan figures are from Intan's product pages, the Neuropixels figures from imec's data sheets, and the SiNAPS figures from the chip records behind the NeuroNexus datasheets.

Choosing a chip#

Four questions decide the chip.

The first is the channel count. The Intan RHD chips cover 16 to 64 channels per chip. SiNAPS records 256 or 1,024 sites, all at once. Neuropixels records 384 channels chosen from 960 to 5,120 sites.

The second is stimulation. Stimulation through the recording electrodes requires the RHS2116, and the other chips record only.

The third is resolution and noise. The Intan chips have the highest resolution and the lowest noise, 16 bits and 2.4 µV rms (typical). SiNAPS and Neuropixels 2.0 digitize at 12 bits and Neuropixels 1.0 at 10 bits, with spike-band noise from 5.9 to about 7 µV rms across the three.

The fourth is the weight on the animal. The headstage, rather than the chip, sets it, and NeuroNexus Data Acquisition Systems: Platform Overview compares the headstages.

DAQ chips in NeuroNexus products#

Each NeuroNexus headstage is built around one or two DAQ chips, and the chip sets the channel count, the noise floor, and the stimulation capability of the headstage.

Further reading#

Citations#

  1. Intan Technologies. RHD2000 Amplifier Chips. intantech.com/products_RHD2000.html ↗
  2. Intan Technologies. RHS2000 Stimulation/Amplifier Chips. intantech.com/products_RHS2000.html ↗
  3. Jun, J. J., et al. (2017). Fully integrated silicon probes for high-density recording of neural activity. Nature 551, 232–236. 10.1038/nature24636 ↗
  4. Steinmetz, N. A., et al. (2021). Neuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings. Science 372, eabf4588. 10.1126/science.abf4588 ↗
  5. Angotzi, G. N., et al. (2019). SiNAPS: An implantable active pixel sensor CMOS-probe for simultaneous large-scale neural recordings. Biosensors and Bioelectronics 126, 355–364. 10.1016/j.bios.2018.10.032 ↗
  6. Angotzi, G. N., et al. (2025). Multi-shank 1024 channels active SiNAPS probe for large multi-regional topographical electrophysiological mapping of neural dynamics. Advanced Science 12(16), 2416239. 10.1002/advs.202416239 ↗

Ask

Cart

History

Resources

Describe your setup and we'll match you to the right probe

Products, compatibility, documents and how to choose. Quotes and orders go to our team.

Oaks 0.8α

Ctrl+K

Save products while browsing — they'll appear here

Look for the "Add to cart" button on product pages

Log in to see your conversation history and quotes

Sign in

Featured resources

Contextual documents and guides will appear here based on the current page.