Skip to content
Inventory sale through Dec 19: B-stock 25–50% off, in-stock A-stock 15% off online.New site. Inventory sale through Dec 19.What's newSee us at SfNSee us at SfN →
NeuroNexus Vector arrays assembled in their packages, with connectors and cables

Electrode Packages

Connector and cable assemblies that complete a probe for your preparation and headstage.

Browse packagesFind the right package

What a probe package is

A finished probe has two parts. The electrode array is the microfabricated part: the shanks with their sites and the bond pads at the base. The package is everything assembled onto that base to make the array usable: the interconnect from the bond pads to the connector, the connector a headstage mates to, the covering over the bond region, and the ground and reference wires. The same array is ordered on different packages for different preparations, and the package is built onto the array at assembly, so it is decided once.

Reading a package name

Series plus channel count: A32 is an A-Series package with 32 channels, CM32 a CM package, H64 a Hybrid. A leading O marks an optoelectrode build, MR an MRI-conditional build, VC a chronic Vector build.

Why it matters as much as the array

The package decides how the probe is held, which headstage can read it, how much it weighs on the animal (0.14 g for a Hybrid to 4.6 g for an A-Series board), where reference and ground come out, and how long the implant survives.

Held to the same standard

The bonds, the encapsulation, and the body carry the mechanical load the array never sees; NeuroNexus assembles and inspects every package and tests every site before it ships.

Choosing a probe packageWhat makes a thin-film electrode good

Three questions select the package

The array is chosen for the target; the package is chosen for the preparation and the rig. Three questions, in the order they bind.

01.

Acute or chronic?

An acute package is built to be held in a manipulator, used for a session, cleaned, and used again (A-Series, ZIF, EIB). A chronic package is built to be worn: cemented to the skull for weeks to months, with fixation, strain relief, and connector durability (CM, X-Series, Hybrid, Vector chronic builds).

02.

What can the subject bear?

Weight and profile decide between CM (connector on the assembly, no cable, the usual chronic package for a mouse), X-Series (the smallest footprint and mass), and Hybrid (a flexible cable that uncouples the probe from the connector, for floating implants and microdrives).

03.

Which headstage will read it?

The connector fixes the headstage: Omnetics for NeuroNexus and most third-party headstages, Hirose for TDT ZIF-Clip, Molex X3 for X-Series headstages, and Activus packages with the digitizing chip built in. Where a pairing is not native, an adapter joins them.

Which adapter?

Find the right package

Select by experimental preparation, by series, or by the connector your headstage uses.

What a package is

The two parts of a probe, how a package name reads, and why the package matters as much as the array.

Start from your experiment

Packages grouped by experimental preparation.

Or by series

Packages grouped by series. Each photo shows one package from the series.

The package in the recording chain

01.

Probe

The silicon probe design: site count, shank count and site pitch. Select by geometry in the design space.

Open the Electrode Finder

02.

Package

The connector, cable and housing attached to the probe. Its connector sets which headstages are compatible.

03.

Headstage

Plugs into the package connector and amplifies or digitizes the signal. Compatible headstages are listed on each package datasheet.

See headstages

04.

Data acquisition system

The hardware the headstage connects to: SmartBox, XDAQ or a compatible third-party system. It streams the recording to the acquisition software.

See systems

05.

Acquisition — Radiens Allego

Instrument control, recording and live monitoring of every channel, with PSTHs during acquisition. Allego runs with every NeuroNexus system.

See Radiens

06.

Analysis and curation — Radiens Videre

File-based analysis and visualization after the recording: spike sorting, LFP analysis and curation, with quality and provenance recorded on every file and NWB read and write.

See Radiens

Connector families

The connector types used in NeuroNexus packages. Each entry links to the packages built with that connector.

Select a package

Compare packages in the webstore

Package cards with connector, channel count, weight and compatible headstages, side by side.

Open the webstore
Start from the probe

Filter probe designs by package series with the Built in facet, then select the package on the probe datasheet.

Open the Electrode Finder

Electrode Packages — FAQ

A probe package is the connector assembly built onto the electrode array: the interconnect from the bond pads to the connector (a rigid board, a flexible cable, or none where the connector sits on the assembly), the connector a headstage mates to, the covering over the bond region, and the ground and reference wires. A finished probe is the array plus the package, the same array is ordered on different packages, and the package is built on at assembly, so it is decided once. It is selected by the experimental preparation (acute, chronic, freely moving), what the subject can bear, and plug-in compatibility with the headstage; a package name reads as series plus channel count (A32, CM32, H64).

Select the package based on plug-in compatibility with your headstage. Connectors by series: Omnetics on most Hybrid, CM, Vector, Fusion, Matrix and DBS packages; Hirose on ZIF packages, which mate with TDT Zif-Clip headstages; Molex X3 or Panasonic on X-Series packages; Samtec on most A-Series packages and on SiNAPS packages; µHDMI or Omnetics 12 on Activus packages; CQ4 on Q-Trode packages. The Compatibility section of each package datasheet lists the compatible headstages.

CM and Hybrid packages are used for chronic implants in mice. CM packages are cableless, with the connector on the assembly, from 0.16 g. Hybrid packages use a flexible polyimide cable between the probe and the connector, from 0.14 g. Select Hybrid when the connector must sit away from the probe shank.

No. The package is built onto the probe at assembly, and a probe in a different package is a different product. Select the package based on the experimental preparation and plug-in compatibility with your headstage, and order spares in the same package.

A (A-Series): a rigid printed-circuit interconnect for acute and intra-operative recording. H (Hybrid): a flexible polyimide cable between probe and connector, for chronic implants. Z (ZIF): zero-insertion-force connectors that mate with TDT Zif-Clip headstages. CM: a cableless package for chronic implants. X (X-Series): the smallest-footprint packages, which mate directly with X-Series headstages. Each package series has a glossary entry.

Yes. MRI-conditional packages carry the MR prefix (for example MRH, MRHC, MRCM and MRA) and use non-magnetic connectors. An MRI-conditional package is selected at order; a standard package cannot be converted to an MRI-conditional one.

Measured package weights range from 0.14 g (Hybrid) to 4.6 g (A-Series). Where a package weight has been measured, it is listed on the package datasheet.

Not sure which package?

A NeuroNexus scientist can recommend a package for your probe, headstage and preparation.

Talk to a scientistGet pricing
NeuroNexus

Neural probes, data acquisition systems, and analytics software for neuroscience research. Designed and manufactured in Ann Arbor, Michigan.

sales@neuronexus.com
+1 734 913 8858

640 Avis Drive, Suite 200, Ann Arbor, MI 48108

Products

All rights reserved. Copyright © 2026 NeuroNexus.
PoliciesPrivacy policy

Consultation

Cart

History

Resources

Describe your setup and we'll match you to the right probe

Oaks 0.8α

Ctrl+K

Save products while browsing — they'll appear here

Look for the "Add to cart" button on product pages

Log in to see your conversation history and quotes

Sign in

Featured resources

Contextual documents and guides will appear here based on the current page.

Prefer a person? Talk to an Application Scientist