53 of 53 questions

Common questions about electrode arrays, probe specifications, packaging, and compatibility with recording systems.

What probe types are available?

NeuroNexus makes silicon neural probes — 210+ catalog designs in 2,000+ variants — and thin-film polymer grid arrays, 50+ catalog designs, for penetrating and surface recording, plus specialty electrodes for stimulation, optogenetics and drug delivery.

How do I choose the right probe and system for my experiment?

Start from whatever is fixed first: browse electrodes by target, modality, or signal, or use the Product Finder to go from your requirements to a matched configuration. Solution Bundles pair probes, acquisition, and accessories that work together as a starting point you customize, and application scientists will help you equip the study end to end.

What is a probe package?

A probe package is the connector assembly built onto the electrode array: the interconnect from the bond pads to the connector (a rigid board, a flexible cable, or none where the connector sits on the assembly), the connector a headstage mates to, the covering over the bond region, and the ground and reference wires. A finished probe is the array plus the package, the same array is ordered on different packages, and the package is built on at assembly, so it is decided once. It is selected by the experimental preparation (acute, chronic, freely moving), what the subject can bear, and plug-in compatibility with the headstage; a package name reads as series plus channel count (A32, CM32, H64).

What is an H-style package?

An H-style (Hybrid) package mounts a silicon probe to one end of a thin-film polyimide ribbon cable, with the other end of the cable attached to a PCB and connector. The assembly mechanically uncouples the probe from the connector; the thin-film cable is very flexible and can even twist slightly. The "H" stands for hybrid assembly, the hybrid of a thin-film silicon probe and a thin-film polymer component, silicon and polymer. It is the chronic package for a floating implant, a microdrive or connector stand-off, at 16 to 128 channels on Omnetics, Hirose or MRI Omnetics connectors.

Do you have an Omnetics 32 to Omnetics 16 adapter?

Yes. It is a configuration of the NeuroNexus connector-pair adapter: input connector Omnetics 32, output connector Omnetics 16 (SKU adpt_nnx--pair.om32.om16, NetSuite item Adpt.Omnetics32-Omnetics16). A 2× version splits one Omnetics 32 onto two Omnetics 16 (adpt_nnx--pair.om32.om16.x2), and the reverse direction, Omnetics 16 to Omnetics 32, is adpt_nnx--pair.om16.om32. Choose the pairing on the adapter's product page and request a quote from the cart.

What do A16, A32, A64, Z16, Z32, OM16 and OM32 mean on an adapter?

They are NeuroNexus package connector codes. A16 is the 16-channel A-series package on a DIP-16 (Mill-Max) connector; A32 is the 32-channel A-series package on a Samtec 40-pin connector; A64 is two Samtec 40. Z16, Z32 and Z64 are Hirose ZIF connectors for TDT ZIF-Clip headstages. OM16, OM32 and OM64 are Omnetics nano connectors with 16, 32 and 64 channels; OM8 is the 8-channel Omnetics. CQ4 and Q4 are the edge connectors on Q-Trode packages. An adapter name reads input to output: A32 → Omnetics 32 takes an A32 package and presents an Omnetics 32.

Which single-shank 32-site polytrode has the smallest site spacing?

With the same 177 µm² sites: the Poly3 25s designs, A1x32-Poly3-5mm-25s-177 and A1x32-Poly3-10mm-25s-177, three staggered columns with 25 µm between neighboring sites and a site every 12.5 µm along the shank. There is no 32-site Poly2 design with closer spacing than 50s (A1x32-Poly2-3mm, 5mm and 10mm-50s-177: 50 µm between neighbors, a site every 25 µm along the shank), and A1x32-Poly3-6mm-50-177 is 50 µm with unstaggered columns. At other site areas, the Poly5 designs are tighter still: A1x32-Poly5-6mm-35s-100 (17.5 µm along the shank, 98 µm² sites) and A1x32-Poly5-6mm-40s-225 (20 µm, 220 µm² sites). If 64 sites are acceptable, V1x64-Poly3-10mm-25s-177 (12.5 µm along the shank, on a Vector support body) and A1x64-Poly2-6mm-23s-160 (23 µm) are the catalog options; the package and headstage change with the site count. In a name, the number before the site area is the spacing between neighboring sites and an s means the columns are staggered; the along-shank pitch is on the datasheet.

Why does silicon probe thickness matter?

Substrate thickness sets bending stiffness, the tissue the shank displaces, handling, and how deep a probe can be driven without buckling. Catalog designs come at 15 and 50 µm: the thinner substrate displaces less tissue and bends more; the thicker holds a straight trajectory on long insertions. For deep targets in large animals the Vector Array mounts a 10 to 15 mm silicon array on a rigid 70 or 110 mm support body. The process also reaches 5 µm, a thickness at which less tissue encapsulation has been reported (Seymour and Kipke, 2007); that is a capability discussed per design, not a catalog line.

Can NeuroNexus silicon probes be used in chronic studies?

Yes. NeuroNexus silicon probes are used in acute and chronic studies, and the published chronic record runs to months: Okun et al. (2016) reported long-term recordings with immobile silicon probes in mouse cortex, Haghighi et al. (2025) implanted four-shank silicon arrays in rat somatosensory cortex for 16 weeks, and Mueller et al. (2025) used a 16-site NeuroNexus probe as the silicon comparator in a 12-week chronic study in rat. The amorphous silicon carbide insulation is the material choice behind chronic lifetime, and the package decides the implant method.

Can NeuroNexus probes be used in species from fruit flies to non-human primates?

Yes. The catalog spans the site counts, shank lengths, geometries and thicknesses the range of animal models needs. Published examples run from Drosophila (Van De Poll and van Swinderen, 2025, long-term multichannel recordings across sleep and wake) to macaques (Thirunavukkarasu et al., 2026, laminar probes in the supplementary eye field; Perich et al., 2026, deep brain structures with Vector Arrays). The citation database holds the rest.

Why do two probes with the same specification perform differently?

A specification describes a design; a probe is a design that has been through a process and a package. Site size, trace width, dielectric integrity, bond quality, and encapsulation all have tolerances that never appear on a spec sheet and each changes what the probe records. NeuroNexus controls the four determinants of quality, design, fabrication process, materials, and package assembly, on one proprietary process, so every probe of a design is identical rather than similar. The determinants and how to check them are in What Makes a Thin-Film Electrode Good.

What quality control does every NeuroNexus probe get?

Every catalog design has a documented datasheet, and every probe of a design is made under the same batch conditions on the same proprietary process. Arrays are inspected after release from the wafer, and after packaging every site is impedance-tested; that factory measurement is recorded and is the baseline a laboratory compares against on first use and after every session. Site yield and impedance consistency are tracked from probe to probe and lot to lot. NeuroNexus controls the design, the process, and the intellectual property end to end.

How do I verify a probe before a recording session?

Measure the impedance of every site in saline before mounting and compare the distribution with the probe's own baseline: the factory record on first use, your last measurement afterward. A good array reads tightly, for 177 µm² iridium sites mostly between 200 kΩ and 1 MΩ at 1 kHz; a site far above the cluster has a broken trace, an open bond, or a contaminated surface, one far below has a short. Inspect under a microscope for clean, uniform sites and intact bonds, and keep a per-site log across sessions. Silicon Probes: Setup, Handling, Cleaning and Care walks through it.

What does the NeuroNexus publication record mean for my study?

NeuroNexus technology has appeared in more than 5,000 peer-reviewed publications across neuroscience and bioengineering, in more than 1,000 laboratories on six continents, in species from fruit flies to non-human primates and in acute and months-long chronic preparations. For a study it means the probe geometry, materials, and packages have been used and reported under conditions close to yours, that reviewers know the devices, and that NeuroNexus probes are the comparator other groups measure new probe designs against. The NeuroNexus scientific publication database lists the publications by product family.

What support comes with a NeuroNexus order?

Application Scientists help match the probe geometry and package to the preparation before the order and remain an inquiry or a phone call away afterward; NeuroNexus engineers and scientists hold more than 150 years of cumulative neural-interface design experience and run NIH-funded research programs. Every order is backed by the documentation on this site: surgical guides for acute and chronic preparations, setup, handling, cleaning, and care procedures, a glossary of every design parameter, connectivity and compatibility guides, and troubleshooting. Custom geometries, materials, and packaging are designed with the laboratory and built on the same process with the same quality controls.

Is there an alternative to Neuropixels?

Yes, two. SiNAPS is the other active-pixel probe: it digitizes on the shank and records every one of its 256 or 1,024 sites at once, where Neuropixels records 384 chosen from 960 to 5,120 sites (1,536 on the Quad Base). Dense passive silicon probes, such as Buzsáki and polytrode layouts, are functionally comparable for some applications and stimulate on the recording sites.

How does SiNAPS compare with Neuropixels?

SiNAPS records every site at once, 1,024 on four or eight shanks, against 384 for Neuropixels 1.0 and 2.0 and 1,536 for the 2.0 Quad Base, which choose their channels from 960 to 5,120 sites. Both are 12-bit, except Neuropixels 1.0 at 10-bit, with comparable noise. Neuropixels has the thinner, 10 mm shank and samples at 30 kS/s against 20. Neither stimulates.

Can I stimulate while recording with Neuropixels?

Not through the Neuropixels probe, which records only. Stimulation goes through a passive probe with stimulation-rated sites on an X-Series record-and-stimulate headstage. The Commutator PRO carries both on one torque-compensated joint, up to four Neuropixels ports and a passive probe at up to 64 record-and-stimulate channels, into XDAQ, so a freely moving animal is stimulated while Neuropixels records.

Which XDAQ records Neuropixels, and how many probes?

Every XDAQ has a Neuropixels mode. The XDAQ ONE+ takes up to four Neuropixels probes, 384 channels each, beside its passive channels; the CORE2 and ALL-IN-ONE record up to 1,024+ Neuropixels channels. XDAQ in NP mode runs on Kontex's acquisition software, which uses the Open Ephys plugin for the Neuropixels interface, and the Kontex NP Headstage connects Neuropixels 1.0 and 2.0 probes.

Can I use a commutator with Neuropixels?

Yes. The Commutator PRO has up to four Neuropixels ports, each taking one Neuropixels 1.0 probe or two Neuropixels 2.0 probes. A gyroscope on the animal follows its turn before the cable twists, or a Hall sensor on the rotor reads the twist, and a motor cancels the torque, so a freely moving animal supplies no force. The Dual Mode model carries a passive probe on its HDMI port at the same time.

How do I find a channel map for a headstage or probe?

Channel maps are PDFs in the Downloads hub. To get one directly, type /map and the part name in the Consultation panel, for example /map SmartLink 32. The answer is a file card that opens, downloads, or copies the link to the map. When a headstage comes in acute and chronic versions, both maps are shown; use the one for the headstage on your rig.

Which commutator: Standard or PRO?

The Standard is passive: the animal's own rotation, through an off-center tether, turns the joint, with no power and no sensor; it suits a rat on a passive probe. The Commutator PRO is motorized: a gyroscope on the animal follows its turn before the cable twists, or a Hall sensor on the rotor reads the twist, and a motor cancels the torque, so none reaches the animal; it suits a mouse, a long session, and any Neuropixels preparation.

Do NeuroNexus silicon probes produce a photoelectric artifact under optogenetic stimulation?

NeuroNexus addresses the artifact at the electrode. Z-Coat site coating suppresses the photoelectric artifact that light produces on a metal recording site and holds through repeated insertion; optrode packages place the fiber so the sites are not lit directly, and the light pulse is timestamped with the neural data through GPIO.

Are NeuroNexus silicon probes microdrive-compatible?

Yes. Chronic probe packages mount on the NeuroNexus dDrive microdrive, and the oDrive adds optical stimulation for chronic optogenetics. Both are catalog products with datasheets and surgical guides.

Which species can NeuroNexus silicon probes be used in?

Mouse to non-human primate. Shank length, site count and package are chosen per target in the Electrode Finder, and every design has a datasheet that states its dimensions.

What is a neural probe?

A neural probe is an implantable device that carries one or more recording or stimulating sites into neural tissue, so that the activity of neurons can be measured, or driven, at a known position. Most are electrical; newer designs add optical and chemical channels on the same shank.

What is the difference between a silicon probe and a wire electrode?

A silicon probe has its sites at positions fixed by a lithographic mask, the same on every probe of a design, so an array can sample a structure in a known pattern; a wire electrode's tip is placed by hand at assembly, so its position varies from array to array. A tetrode, four wires twisted together, isolates units well at one depth; the silicon equivalent is a cluster of sites at a fixed 20 to 25 µm pitch.

How many channels does a neural probe have?

From one site on a microwire to 1,024 on an active-pixel probe. NeuroNexus passive silicon probes have 4 to 256 sites on 1 to 16 shanks; SiNAPS active-pixel probes record 256 or 1,024 sites at once; Neuropixels probes record 384 channels chosen from 960 to 5,120 sites. The count follows from the site layout the measurement needs, and it fixes the headstage and the connector.

How long does a chronic neural probe last?

A chronic implant records for weeks to months. Over the first weeks the tissue settles and glial cells encapsulate the shank, so impedance rises and unit amplitude falls; a thin shank, a floating package, and a light headstage reduce the response, and a microdrive recovers units by advancing the probe a few tens of micrometers. NeuroNexus reported the first chronic performance of silicon probes in cortex in 2003 and 2004.

Can a neural probe be used for optogenetics?

Yes. An optrode package fixes an optical fiber alongside the array, so light is delivered on the trajectory of the recording sites. Light on a metal site produces the photoelectric artifact; NeuroNexus Z-Coat suppresses it at the site, and the optrode package places the fiber so the sites are not lit directly.

How do I choose a neural probe?

By fitting the probe to the target, the measurement, the duration, the species, and the recording system, in that order: species and depth set the shank length, the measurement sets the site layout, the layout sets the channel count, acute or chronic sets the package, and optogenetics adds the fiber. The Electrode Finder applies those decisions to the catalog.

Didn't find your answer?
Our technical team is available to help with specific questions about products, applications, and experimental design.

Consultation

Cart

History

Resources

Describe your setup and we'll match you to the right probe

Products, compatibility, documents and how to choose. Quotes and orders go to our team.

Oaks 0.8α

Ctrl+K

Save products while browsing — they'll appear here

Look for the "Add to cart" button on product pages

Log in to see your conversation history and quotes

Sign in

Featured resources

Contextual documents and guides will appear here based on the current page.