Neural Probe

Hardware
A neural probe is an implantable device with precisely positioned electrode sites that record or stimulate neural activity in a small, targeted region of the brain, spinal cord, or peripheral nerve. Most probes are silicon or polymer and are designed for electrical recording or stimulation, with specialized designs adding optical, chemical, or fluidic modalities.

Neural probes are devices with microscale features, made by thin-film microfabrication on silicon or polymer substrates, and they typically have one to more than a thousand individually addressable electrode sites. Penetrating neural probes are microelectrode arrays with sites on one or more shanks, typically 15–50 µm thick, tens to a few hundred micrometers wide, and from about 1 mm long for cortical targets to more than 10 cm long for deep structures in large animals. Surface neural probes, also called grid electrodes or thin-film grids, are polymer electrode arrays with a precise layout of sites that spans a few millimeters to several centimeters and conforms to the surface of the target tissue. The same grids are also used to record from the surface of the heart.

Most probes record extracellular biopotentials, typically 20 µV to several millivolts, which include action potentials (spikes) and local field potentials. With appropriate site size and materials, the same sites can safely and reversibly stimulate neural tissue with small, charge-balanced current pulses, typically 10 to 200 µA. Specialized designs add chemical sensing, fluid delivery through microchannels, and optical stimulation through optical fibers or integrated micro-LEDs.

A neural probe is a biopotential electrode. It belongs to the same class as ECG, EEG, and ECoG electrodes and metal microelectrodes, and it is governed by the same physics. Each electrode site is an electrochemical interface that converts the ionic current in tissue into electronic current in a metal conductor. Its position, area, and material determine what it senses, how selectively, and with how much intrinsic noise. The measured signal is the extracellular potential at each site relative to a reference, which is the sum of the transmembrane currents in the surrounding volume. EEG, ECoG, and the local field potential are therefore the same signal, named by where the electrode is placed (Buzsáki et al. (2012)).

A neural probe differs from a single microelectrode in that it has many sites at positions fixed by the design, so one device samples a population of neurons at multiple, known locations. Site spacing determines, in part, what the probe resolves. Spike amplitude typically falls to the background noise within about 50 to 150 µm of the cell body (the detection radius), while the field potential extends across the structure. Sites 50 µm apart or less can record the same spike, which allows spike sorting to separate and localize units. Sites 200 µm or more apart typically sample different neurons, which is suited to laminar profiling and current source density analysis (Drake et al. (1988); Buzsáki (2004)).

Four types of neural probe are in common use. A silicon probe has its sites at positions fixed by a lithographic mask, so the positions are the same on every probe of a design. It descends from the Michigan probe of 1970 (Wise et al. (1970)), and NeuroNexus offers more than 210 catalog designs. A microwire or tetrode has its tip positioned by hand. A thin-film grid is a flexible polymer array for a tissue surface. An active-pixel probe has an amplifier under each site and is digitized on the probe, with up to about a thousand sites read out at once.

In the recording chain, the probe is the sensor. A headstage amplifies and digitizes the site voltages, the acquisition system timestamps and stores them with stimulus and behavioral events, and software extracts spikes, field potentials, and their relationships. The white paper Neural Probes: What They Are, How They Work, and How to Choose One describes neural probes in detail. A Brief History of Neural Electrode Technology gives the published record since 1953. The NeuroNexus catalog is at silicon probes. Research use only.

Typical values

Typessilicon (micromachined), wire and tetrode, flexible polymer, CMOS active-pixel
Sites per probe1 (microwire) to 1,024 (active-pixel)
NeuroNexus silicon catalogmore than 210 designs, 4 to 1,024 sites, 1 to 16 shanks, 1.5 to 60 mm
Lineagethe Michigan probe, from 1970

Cite this term

NeuroNexus. "Neural Probe." NeuroNexus Glossary, updated 2026-11-12. https://www.neuronexus.com/resources/glossary/neural-probe


Category:

Hardware

· Physical probe specifications, electrode properties, and hardware concepts

Ask

Cart

History

Resources

Describe your setup and we'll match you to the right probe

Products, compatibility, documents and how to choose. Quotes and orders go to our team.

Oaks 0.8α

Ctrl+K

Save products while browsing — they'll appear here

Look for the "Add to cart" button on product pages

Log in to see your conversation history and quotes

Sign in

Featured resources

Contextual documents and guides will appear here based on the current page.