16-site A-Series probe, 16 shanks, 2 mm, 177 µm², 50 µm apart
Sixteen short shanks side by side, closely spaced for coverage within one structure, with sites spread evenly down each, one per row, for a profile across depth. Among the 369 probe designs in the design space it is in the lower quartile: 16 sites (a common choice — 84 of 369), 2 mm shanks (8th percentile of the 366 measured), a 0.02 mm-deep site array (1st percentile), 1,393 sites/mm² (90th percentile) and a 0.33 mm³ neural interface (16th percentile).
Small sites read a local patch at higher impedance, sharpening single-unit isolation. The short shanks suit superficial targets.
Orders as a probe-plus-package assembly, in 16 package configurations, 1 of them microdrive-compatible. Silicon 15 or 50 µm thick. Z-coat available. Optical stimulation runs from a separate laser or LED source. Research use only.
a16x1_2mm50_177
12 specs
| Channels | 16 |
|---|---|
| Shanks | 16 |
| Shank length | 2 mm |
| Shank separation | 50 µm |
| Site area | 177 µm² |
| Vertical span | 15 µm |
| Substrate | Silicon |
| Site material | Iridium |
| Thickness | 15, 50 µm |
| Neural interface volume | 0.326 mm³ (higher than 16% of 369 designs) |
| Site coverage density | 1,393.2 sites/mm² (higher than 90% of 369 designs) |
| Brain coverage density | 49.1 sites/mm³ (higher than 53% of 369 designs) |
Narrow the options with the filters or pick a card, then contact us to order that configuration.
17 options
Configure
Your selection
16-channel 16-shank silicon probe, 2 mm — 15 μm, A16
A16Options
17 of 1715 μm · A16 — 16-ch
15 μm · CM16 — 16-ch
15 μm · CM16LP — 16-ch Omnetics
15 μm · H16 (21 mm cable) — 16-ch Omnetics
15 μm · HC16 (21 mm cable) — 16-ch Omnetics
15 μm · HP16_21MM — 16-ch
15 μm · HZ16 (21 mm cable) — 16-ch Hirose
15 μm · IVA16 — 16-ch
15 μm · MRCM16 — 16-ch Omnetics
15 μm · OA16LP — 16-ch
15 μm · OCM16 — 16-ch
15 μm · OCM16LP — 16-ch Omnetics
15 μm · OH16LP — 16-ch Omnetics
15 μm · X3_16 — 16-ch Molex
15 μm · X3_H16 (21 mm cable) — 16-ch Molex
15 μm · Z16 — 16-ch Hirose
50 μm · IVA16 — 16-ch
Loading the compatible products…
12 metrics
Each track spans the smallest to the largest value across catalog designs. The band is the range within its family, and the dot is this design's value. “Top N%” is a rank: how many designs have a larger value.
Top 70% of catalog designs
Sites 16 — higher than 30% of catalog designs and 34% of its familyLargest among catalog designs · largest in its family
Shanks 16 — higher than 100% of catalog designs and 100% of its family (the largest in its family, 180 designs)Top 92% of catalog designs
Shank length 2 mm — higher than 8% of catalog designs and 8% of its familyTop 98% of catalog designs
Shank separation 0.05 mm — higher than 2% of catalog designs and 4% of its familyTop 96% of catalog designs
Maximum site depth 1.96 mm — higher than 4% of catalog designs and 4% of its familyTop 86% of catalog designs
Minimum site depth 1.94 mm — higher than 14% of catalog designs and 14% of its familyTop 28% of catalog designs
Span, x 0.765 mm — higher than 72% of catalog designs and 71% of its familyTop 99% of catalog designs
Span, y 0.015 mm — higher than 1% of catalog designs and 2% of its familyTop 91% of catalog designs
Site outline area 0.011 mm² — higher than 9% of catalog designs and 7% of its familyTop 84% of catalog designs
Neural interface volume 0.326 mm³ — higher than 16% of catalog designs and 9% of its familyTop 10% of catalog designs
Site coverage density 1393.2 sites/mm² — higher than 90% of catalog designs and 89% of its familyTop 47% of catalog designs
Brain coverage density 49.12 sites/mm³ — higher than 53% of catalog designs and 59% of its family3 notes · Geometry · Construction · Packaging and connector options
22 links · A Brief History of Neural Electrode Technology · Care, Use and Handling · Choosing an Electrode for Your Experiment …
Cited in 2,342 publications (product line)