Skip to content
Inventory sale through Dec 19: B-stock 25–50% off, in-stock A-stock 15% off online.New site. Inventory sale through Dec 19.What's newSee us at SfNSee us at SfN →
Neural Probes · A-Series

Linear Single-Shank 16-Channel Probe, 5 mm

16Sites
1Shanks
5mmShank Length
100µmSite Pitch
Part no.A1x16-5mm-100-60/72
Contact us to order
Contents

16-site A-Series probe, 1 shank, 5 mm

A single mid-length shank with sites spread evenly down the shank, one per row, for a profile across depth. Among the 369 probe designs in the design space it is mid-range: 16 sites (a common choice — 84 of 369), 5 mm shanks (a common choice — 108 of 366), a 1.53 mm-deep site array (72nd percentile), 352 sites/mm² (60th percentile) and a 0.54 mm³ neural interface (41st percentile).

spaced for a laminar profile. The mid-length shank reaches structures a few millimetres down.

Orders as a probe-plus-package assembly, in 69 package configurations, 5 of them microdrive-compatible. Silicon 15 µm thick. Z-coat available. Research use only.

Also known as

A1x16-5mm-100-60/72 · a1x16-5mm-100-60/72

Linear Single-Shank 16-Channel Probe, 5 mmSKU prb_acl--a1x16_5mm_100_60_72NetSuite 5111

Estimated geometry — the site layout is not from a measured design file, so geometry-derived values are approximate.

11 specs

Channels16
Shanks1
Shank length5 mm
Site pitch100 µm
Vertical span1530 µm
SubstrateSilicon
Thickness15 µm
Site geometryEstimated from the design name and similar designs
Neural interface volume0.538 mm³ (higher than 41% of 369 designs)
Site coverage density352.5 sites/mm² (higher than 60% of 369 designs)
Brain coverage density29.8 sites/mm³ (higher than 24% of 369 designs)
NetSuite ID

5111

Linear Single-Shank 16-Channel Probe, 5 mmSKU prb_acl--a1x16_5mm_100_60_72NetSuite 5111

Narrow the options with the filters or pick a card, then contact us to order that configuration.

2 options

Configure

Compatible Package
All
A16 — 16-ch
CM16 — 16-ch

Your selection

16-channel single-shank silicon probe, 5 mm — 15 μm, A16
A16
Compatible Package: A16 — 16-ch
SKUprb_acl--a1x16_5mm_100_60_72_a16

Options

2 of 2
Linear Single-Shank 16-Channel Probe, 5 mmSKU prb_acl--a1x16_5mm_100_60_72NetSuite 5111

Loading the compatible products…

Linear Single-Shank 16-Channel Probe, 5 mmSKU prb_acl--a1x16_5mm_100_60_72NetSuite 5111

Estimated geometry — the site layout is not from a measured design file, so geometry-derived values are approximate.

12 metrics

Each track spans the smallest to the largest value across catalog designs. The band is the range within its family, and the dot is this design's value. “Top N%” is a rank: how many designs have a larger value.

Sites
16
41024

Top 70% of catalog designs

Sites 16 — higher than 30% of catalog designs and 34% of its family
Shanks
1
116

Top 58% of catalog designs

Shanks 1 — higher than 42% of catalog designs and 40% of its family
Shank length
5 mm
1 mm60 mm

Top 48% of catalog designs

Shank length 5 mm — higher than 52% of catalog designs and 61% of its family
Maximum site depth
4.96 mm
0.972 mm51.29 mm

Top 55% of catalog designs

Maximum site depth 4.96 mm — higher than 45% of catalog designs and 57% of its family
Minimum site depth
3.44 mm
0.067 mm44.74 mm

Top 69% of catalog designs

Minimum site depth 3.44 mm — higher than 31% of catalog designs and 37% of its family
Span, x
0.03 mm
0.01 mm6.03 mm

Top 73% of catalog designs

Span, x 0.03 mm — higher than 27% of catalog designs and 36% of its family
Span, y
1.53 mm
0.01 mm10.55 mm

Top 28% of catalog designs

Span, y 1.53 mm — higher than 72% of catalog designs and 74% of its family
Site pitch, y
0.1 µm
0.01 µm1.5 µm

Top 17% of catalog designs

Site pitch, y 0.1 µm — higher than 83% of catalog designs and 80% of its family
Site outline area
0.045 mm²
0.002 mm²28.74 mm²

Top 72% of catalog designs

Site outline area 0.045 mm² — higher than 28% of catalog designs and 31% of its family
Neural interface volume
0.538 mm³
0.149 mm³17.19 mm³

Top 59% of catalog designs

Neural interface volume 0.538 mm³ — higher than 41% of catalog designs and 36% of its family
Site coverage density
352.5 sites/mm²
1.66 sites/mm²3047.2 sites/mm²

Top 40% of catalog designs

Site coverage density 352.5 sites/mm² — higher than 60% of catalog designs and 65% of its family
Brain coverage density
29.76 sites/mm³
2.49 sites/mm³393.9 sites/mm³

Top 76% of catalog designs

Brain coverage density 29.76 sites/mm³ — higher than 24% of catalog designs and 22% of its family
Linear Single-Shank 16-Channel Probe, 5 mmSKU prb_acl--a1x16_5mm_100_60_72NetSuite 5111

3 notes · Geometry · Construction · Packaging and connector options

Linear Single-Shank 16-Channel Probe, 5 mmSKU prb_acl--a1x16_5mm_100_60_72NetSuite 5111

22 links · A Brief History of Neural Electrode Technology · Care, Use and Handling · Choosing an Electrode for Your Experiment …

Linear Single-Shank 16-Channel Probe, 5 mmSKU prb_acl--a1x16_5mm_100_60_72NetSuite 5111

Cited in 2,342 publications (product line)

Ask

Cart

History

Resources

Ask us anything about this probe

Products, compatibility, documents and how to choose. Quotes and orders go to our team.

Oaks 0.8α

Ctrl+K

Save products while browsing — they'll appear here

Look for the "Add to cart" button on product pages

Log in to see your conversation history and quotes

Sign in

Resources for this product

Datasheets, application notes, and videos will appear here when connected to the content registry.