32-site A-Series probe, 1 shank, 15 mm, 177 µm², 100 µm pitch
A single long shank with sites spread evenly down the shank, one per row, for a profile across depth. Among the 369 probe designs in the design space it is in the upper quartile: 32 sites (a common choice — 158 of 369), 15 mm shanks (98th percentile of the 366 measured), a 3.11 mm-deep site array (88th percentile), 692 sites/mm² (72nd percentile) and a 0.93 mm³ neural interface (67th percentile).
Small sites read a local patch at higher impedance, sharpening single-unit isolation, spaced for a laminar profile. The long shank reaches deep targets.
Orders as a probe-plus-package assembly, in 18 package configurations. Silicon 15 or 50 µm thick. Z-coat available. Optical stimulation runs from a separate laser or LED source. Research use only.
a1x32_15mm100_177
12 specs
| Channels | 32 |
|---|---|
| Shanks | 1 |
| Shank length | 15 mm |
| Site area | 177 µm² |
| Site pitch | 100 µm |
| Vertical span | 3115 µm |
| Substrate | Silicon |
| Site material | Iridium |
| Thickness | 15, 50 µm |
| Neural interface volume | 0.931 mm³ (higher than 67% of 369 designs) |
| Site coverage density | 692.1 sites/mm² (higher than 72% of 369 designs) |
| Brain coverage density | 34.4 sites/mm³ (higher than 37% of 369 designs) |
Narrow the options with the filters or pick a card, then contact us to order that configuration.
22 options
Configure
Your selection
32-channel single-shank silicon probe, 15 mm — 15 μm, A32
A32Options
22 of 2215 μm · A32 — 32-ch Samtec
15 μm · CM32 — 32-ch Omnetics
15 μm · H32 (21 mm cable) — 32-ch Omnetics
15 μm · HC32 (21 mm cable) — 32-ch Omnetics
15 μm · HP32_21MM — 32-ch
15 μm · HZ32 (21 mm cable) — 32-ch Hirose
15 μm · MRCM32 — 32-ch
15 μm · OA32 — 32-ch
15 μm · OA32LP — 32-ch Samtec
15 μm · OCM32 — 32-ch
15 μm · OCM32LP — 32-ch Omnetics
15 μm · OH32LP (21 mm cable) — 32-ch Omnetics
15 μm · OXA32LP — 32-ch Samtec
15 μm · OZ32 — 32-ch
15 μm · OZ32LP — 32-ch Hirose
15 μm · X3_32 — 32-ch Molex
15 μm · X3_H32 (21 mm cable) — 32-ch Molex
15 μm · Z32 — 32-ch Hirose
50 μm · CM32 — 32-ch Omnetics
50 μm · A32 — 32-ch Samtec
50 μm · H32 (21 mm cable) — 32-ch Omnetics
50 μm · OA32LP — 32-ch Samtec
Loading the compatible products…
12 metrics
Each track spans the smallest to the largest value across catalog designs. The band is the range within its family, and the dot is this design's value. “Top N%” is a rank: how many designs have a larger value.
Top 26% of catalog designs
Sites 32 — higher than 74% of catalog designs and 79% of its familyTop 58% of catalog designs
Shanks 1 — higher than 42% of catalog designs and 40% of its familyTop 2% of catalog designs
Shank length 15 mm — higher than 98% of catalog designs and 99% of its familyTop 4% of catalog designs
Maximum site depth 14.96 mm — higher than 96% of catalog designs and 98% of its familyTop 5% of catalog designs
Minimum site depth 11.84 mm — higher than 95% of catalog designs and 98% of its familyTop 85% of catalog designs
Span, x 0.015 mm — higher than 15% of catalog designs and 16% of its familyTop 12% of catalog designs
Span, y 3.11 mm — higher than 88% of catalog designs and 91% of its familyTop 17% of catalog designs
Site pitch, y 0.1 µm — higher than 83% of catalog designs and 80% of its familyTop 69% of catalog designs
Site outline area 0.046 mm² — higher than 31% of catalog designs and 34% of its familyTop 33% of catalog designs
Neural interface volume 0.931 mm³ — higher than 67% of catalog designs and 66% of its familyTop 28% of catalog designs
Site coverage density 692.1 sites/mm² — higher than 72% of catalog designs and 76% of its familyTop 63% of catalog designs
Brain coverage density 34.39 sites/mm³ — higher than 37% of catalog designs and 41% of its family3 notes · Geometry · Construction · Packaging and connector options
22 links · A Brief History of Neural Electrode Technology · Care, Use and Handling · Choosing an Electrode for Your Experiment …
Cited in 2,342 publications (product line)