SiNAPS 1-Shank 256-Channel Probe
256-site active-pixel silicon probe
A single mid-length shank with an active pixel beneath every site. Among the 369 probe designs in the design space it sits at the top: 256 sites (99th percentile), 5.5 mm shanks (54th percentile of the 366 measured), a 3.77 mm-deep site array (93rd percentile), 1,560 sites/mm² (92nd percentile) and a 1.16 mm³ neural interface (77th percentile).
Small sites read a local patch at higher impedance, sharpening single-unit isolation, packed densely enough to track a unit across neighbouring sites. The mid-length shank reaches structures a few millimetres down.
Orders as a probe-plus-package assembly, in 3 package configurations. Silicon 50 µm thick. Optical stimulation runs from a separate laser or LED source. Research use only.
sinaps_1s_256
23 specs
| Channels | 256 |
|---|---|
| Shanks | 1 |
| Shank length | 5.5 mm |
| Site layout | Pixel |
| Site area | 196 µm² |
| Site pitch | 30 µm |
| Vertical span | 3768 µm |
| Substrate | Silicon |
| Site material | Platinum |
| Thickness | 50 µm |
| Neural interface volume | 1.160 mm³ (higher than 77% of 369 designs) |
| Site coverage density | 1,559.5 sites/mm² (higher than 92% of 369 designs) |
| Brain coverage density | 220.7 sites/mm³ (higher than 98% of 369 designs) |
|---|---|
| Architecture | Active pixel sensor |
| In-pixel gain | 46 dB (DC-4 kHz) |
| Input noise | 6.5 µVrms (300-5000 Hz) |
| Sampling rate | 20 kSample/s per pixel |
| Multiplexing | 32:1 |
| Power | <6 µW per electrode-pixel |
| Electrode pitch | 30 ± 1 µm |
| Shank length | 5656 ± 60 µm |
| Active length | 3865 ± 1 µm |
| Shank width | 88 ± 2 µm |
Narrow the options with the filters or pick a card, then add the configuration to your cart. When your cart is complete, get pricing, lead time and usage details in one request; we reply within one business day.
3 options
Configure
Your selection
256-site active-pixel silicon probe, 1 shank, 5.5 mm — 50 μm, AVS256
AVS256Options
3 of 3AVS256 — 256-ch Samtec
AVSH256 — 256-ch Samtec
OAVS256 — 256-ch Samtec
Amplification, filtering and multiplexing sit directly beneath each electrode-pixel — so signal is conditioned and digitized on the shank, not in an external headstage. That is what lets an active-CMOS probe reach thousands of simultaneous channels a passive probe cannot.
46 dB
In-pixel gain32:1
Multiplexing<6 µW
Power / pixel20 kS/s
Per-pixel sampling6.5 µVrms
Input noiseLoading the compatible products…
13 metrics
Each track spans the smallest to the largest value across catalog designs. The band is the range within its family, and the dot is this design's value. “Top N%” is a rank: how many designs have a larger value.
Top 1% of catalog designs
Sites 256 — higher than 99% of catalog designs and 33% of its familyTop 58% of catalog designs
Shanks 1 — higher than 42% of catalog designs and 33% of its familyTop 46% of catalog designs · largest in its family
Shank length 5.5 mm — higher than 54% of catalog designs and 100% of its family (the largest in its family, 3 designs)Top 46% of catalog designs · largest in its family
Maximum site depth 5.35 mm — higher than 54% of catalog designs and 100% of its family (the largest in its family, 3 designs)Top 90% of catalog designs
Minimum site depth 1.58 mm — higher than 10% of catalog designs and 67% of its familyTop 70% of catalog designs
Span, x 0.044 mm — higher than 30% of catalog designs and 33% of its familyTop 7% of catalog designs · largest in its family
Span, y 3.77 mm — higher than 93% of catalog designs and 100% of its family (the largest in its family, 3 designs)Top 30% of catalog designs
Site pitch, x 0.03 µm — higher than 70% of catalog designs and 67% of its familyTop 67% of catalog designs
Site pitch, y 0.03 µm — higher than 33% of catalog designs and 67% of its familyTop 49% of catalog designs
Site outline area 0.164 mm² — higher than 51% of catalog designs and 33% of its familyTop 23% of catalog designs
Neural interface volume 1.16 mm³ — higher than 77% of catalog designs and 33% of its familyTop 8% of catalog designs · largest in its family
Site coverage density 1559.5 sites/mm² — higher than 92% of catalog designs and 100% of its family (the largest in its family, 3 designs)Top 2% of catalog designs
Brain coverage density 220.7 sites/mm³ — higher than 98% of catalog designs and 67% of its family6 notes · Choosing between the two 1,024-site designs · What the active-pixel architecture requires · When one shank is the right choice …
7 downloads · 21 links · 3 videos · High-Density Recording: A Planning Guide · Neural Recording Chips: A Guide to DAQ ASICs · SiNAPS: Active High-Density Microelectrodes …
Cited in 2,342 publications (product line)